dem_status,station_code,station_name,component_code,component_name,component_short_name,zone_objective_code1,zone_code1,zone_name1,zone_objective_code2,zone_code2,zone_name2,measurement_code,measurement_start_date,measurement_end_date,measurement_method_type,measurement_technique_principle,measurement_equipment,integration_time_frequency,integration_time_unit,height_sampling_point,length_sampling_line,location_sampling_point,sampling_time,sampling_time_unit,calibration_frequency,calibration_unit,calibration_method,calibration_description,body_or_programme
"M","IT1029A","","9","","","","","","","","","500","19950902","","automatic analyzer","chemiluminescence","Thermo Envir. Instruments TE42","","","350","300","roof","5","Second","24","Hour","permuation tube","","EU EoI"
"M","IT1029A","","10","","","","","","","","","500","19950902","","automatic analyzer","infrared absorption","Thermo Instr. TE 48","","","350","300","roof","5","Second","24","Hour","compressed gases","","EU EoI"
"M","IT1029A","","38","","","","","","","","","500","19950902","","automatic analyzer","chemiluminescence","Thermo Envir. Instruments TE42","","","350","300","roof","5","Second","24","Hour","permuation tube","","EU EoI"
"M","IT1030A","","7","","","","","","","","","500","19951002","","automatic analyzer","ultraviolet absorption","Thermo Environmental Instruments 49","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT1030A","","8","","","","","","","","","500","19951002","","automatic analyzer","chemiluminescence","Thermo Environmental Instr. 42","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT1030A","","9","","","","","","","","","500","19951002","","automatic analyzer","chemiluminescence","Thermo Environmental Instruments 42","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT1030A","","10","","","","","","","","","500","19951002","","automatic analyzer","infrared absorption","Thermo Environmental Instruments 48","1","Hour","320","","ROOF","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT1030A","","38","","","","","","","","","500","19951002","","automatic analyzer","chemiluminescence","Thermo Environmental Instruments 42","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT1031A","","4","","","","","","","","","500","19960401","20020301","automatic analyzer","gravimetry","ZAMBELLI EXPLORER","","","300","0","roof","1","natural day","0","","","","EU EoI"
"M","IT1031A","","8","","","","","","","","","500","19951002","","automatic analyzer","chemiluminescence","Thermo Environmental Instruments 48","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT1031A","","9","","","","","","","","","500","19951002","","automatic analyzer","chemiluminescence","Thermo Environmental Instruments 48","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT1031A","","10","","","","","","","","","500","19951002","","automatic analyzer","infrared absorption","Thermo Environmental Instruments 48","1","Hour","320","","ROOF","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT1031A","","38","","","","","","","","","500","19951002","","automatic analyzer","chemiluminescence","Thermo Environmental Instruments 48","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT1032A","","1","","","","","","","","","500","19951002","","automatic analyzer","fluorescence","Thermo Environmental Instruments 43 B","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT1032A","","4","","","","","","","","","500","19960401","20001101","automatic analyzer","","","","","300","0","roof","1","natural day","0","","","","EU EoI"
"M","IT1032A","","5","","","","","","","","","500","20001109","","automatic analyzer","beta-absorption","MP101M","1","Hour","1","","ROOF","1","Hour","1","Day","calibration filter","","EU EoI"
"M","IT1032A","","8","","","","","","","","","500","19951002","","automatic analyzer","chemiluminescence","Thermo Environmental Instruments 42","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT1032A","","9","","","","","","","","","500","19951002","","automatic analyzer","chemiluminescence","Thermo Environmental model 42","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT1032A","","10","","","","","","","","","500","19951002","","automatic analyzer","infrared absorption","Thermo Environmental Instruments 48","1","Hour","320","","ROOF","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT1032A","","38","","","","","","","","","500","19951002","","automatic analyzer","chemiluminescence","Thermo Environmental model 42","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT1042A","","4","","","","","","","","","500","19960302","","active sampler","gravimetry","","","","3","0","COURTYARD","1","natural day","3","Month","standard mass","","EU EoI"
"M","IT1042A","","8","","","","","","","","","500","19960302","","automatic analyzer","chemiluminescence","Thermo Environmental model 42","","","3","2","COURTYARD","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT1042A","","9","","","","","","","","","500","19960302","","automatic analyzer","chemiluminescence","Thermo Env. -mod42-","","","3","2","COURTYARD","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT1042A","","10","","","","","","","","","500","19960302","","automatic analyzer","infrared absorption","Thermo Environmental Instruments 48","","","3","2","COURTYARD","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT1042A","","12","","","","","","","","","500","19960302","","active sampler","","","","","3","0","COURTYARD","1","natural day","1","","standard solution","","EU EoI"
"M","IT1042A","","38","","","","","","","","","500","19960302","","automatic analyzer","chemiluminescence","Thermo Environmental Instr. 42","","","3","2","COURTYARD","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT1043A","","4","","","","","","","","","500","19960701","20020731","automatic analyzer","","","","","300","100","roof","1","Hour","1","Year","","","EU EoI"
"M","IT1043A","","5","","","","","","","","","500","19971001","","automatic analyzer","beta-absorption","RANCON ADAM C","","","3","1","PARK","1","natural day","1","Month","","","EU EoI"
"M","IT1043A","","7","","","","","","","","","500","19960302","","automatic analyzer","ultraviolet absorption","Thermo Environmental Instruments 49","","","3","2","PARK","1","Hour","1","Day","uv lamp (ozone generator)","","EU EoI"
"M","IT1043A","","8","","","","","","","","","500","19960302","","automatic analyzer","chemiluminescence","Thermo Env. -mod42-","","","3","2","PARK","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT1043A","","9","","","","","","","","","500","19960302","","automatic analyzer","chemiluminescence","Thermo Environmental Instruments 42","","","3","2","PARK","1","Hour","1","Hour","compressed gases","","EU EoI"
"M","IT1043A","","10","","","","","","","","","500","19960302","","automatic analyzer","infrared absorption","Thermo Env. -mod.48-","","","3","2","PARK","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT1043A","","38","","","","","","","","","500","19960302","","automatic analyzer","chemiluminescence","Thermo Environmental Instruments 42","","","3","2","PARK","1","Hour","1","Day","compressed gases","","EU EoI"
"A","IT1043A","","6001","","","","","","","","","500","20041015","","automatic analyzer","beta-absorption","","","","300","100","PARK","1","natural day","1","Month","","","EU EoI"
"M","IT1044A","","1","","","","","","","","","500","19960302","","automatic analyzer","","Thermo Env. -mod.43B-","","","3","2","KERBSIDE","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT1044A","","4","","","","","","","","","500","19960302","","active sampler","gravimetry","","","","3","0","KERBSIDE","1","natural day","3","Month","standard mass","","EU EoI"
"M","IT1044A","","5","","","","","","","","","500","20020819","","automatic analyzer","beta-absorption","Environnement S.A. MP101M","1","Day","3","2","KERBSIDE","2","Hour","","","","","EU EoI"