dem_status,station_code,station_name,component_code,component_name,component_short_name,zone_objective_code1,zone_code1,zone_name1,zone_objective_code2,zone_code2,zone_name2,measurement_code,measurement_start_date,measurement_end_date,measurement_method_type,measurement_technique_principle,measurement_equipment,integration_time_frequency,integration_time_unit,height_sampling_point,length_sampling_line,location_sampling_point,sampling_time,sampling_time_unit,calibration_frequency,calibration_unit,calibration_method,calibration_description,body_or_programme
"M","IT1105A","","8","","","","","","","","","500","19980201","","automatic analyzer","chemiluminescence","Thermo Environmental model 42","","","250","300","roof","30","Second","15","Day","compressed gases","","EU EoI"
"M","IT1105A","","9","","","","","","","","","500","19980401","","automatic analyzer","chemiluminescence","Thermo Environmental Instr. 42","","","250","300","roof","30","Second","15","Day","compressed gases","","EU EoI"
"M","IT1105A","","10","","","","","","","","","500","19980201","","automatic analyzer","infrared absorption","Thermo Environmental model 48","","","250","300","roof","30","Second","1","Month","compressed gases","","EU EoI"
"M","IT1105A","","20","","","","","","","","","500","20040630","","automatic analyzer","chromatography","","","","","","roof","","","15","Day","compressed gases","","EU EoI"
"A","IT1105A","","38","","","","","","","","","500","19980101","","automatic analyzer","chemiluminescence","Termo Environmental Instruments 42","","","250","300","roof","30","Second","15","Day","compressed gases","","EU EoI"
"M","IT1141A","","1","","","","","","","","","500","19970919","","automatic analyzer","fluorescence","API 100 A","1","Hour","1","","ROOF","1","Hour","1","Hour","permuation tube","","EU EoI"
"M","IT1141A","","5","","","","","","","","","500","19971024","","automatic analyzer","beta-absorption","MP101M","1","Hour","390","","ROOF","1","Hour","1","Day","calibration filter","","EU EoI"
"M","IT1141A","","7","","","","","","","","","500","19970919","","automatic analyzer","ultraviolet absorption","API 400","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT1141A","","8","","","","","","","","","500","19970923","","automatic analyzer","chemiluminescence","API 200 A","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT1141A","","9","","","","","","","","","500","19970923","","automatic analyzer","chemiluminescence","API 200 A","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT1141A","","10","","","","","","","","","500","19971005","","automatic analyzer","infrared absorption","API MOD.300","1","Hour","320","","ROOF","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT1141A","","34","","","","","","","","","500","20000204","20030130","automatic analyzer","chromatography","","","","0","0","roof","0","","0","","","","EU EoI"
"M","IT1141A","","38","","","","","","","","","500","19970923","","automatic analyzer","chemiluminescence","API 200 A","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT1152A","","5","","","","","","","","","500","20010226","","automatic analyzer","oscillating microbalance","TEOM","1","Hour","300","200","ROOF","2","Second","0","","","","EU EoI"
"M","IT1152A","","7","","","","","","","","","500","20040101","","automatic analyzer","ultraviolet absorption","THERMO ELECTRON  INSTRUMENTS 49","","","","","roof","","","6","Month","uv lamp (ozone generator)","","EU EoI"
"M","IT1152A","","8","","","","","","","","","500","19971115","","automatic analyzer","chemiluminescence","API200A","1","Hour","300","200","ROOF","5","Second","3","Day","permuation tube","","EU EoI"
"M","IT1152A","","9","","","","","","","","","500","19971116","","automatic analyzer","chemiluminescence","API 200 A","1","Hour","300","200","ROOF","5","Second","3","Day","permuation tube","","EU EoI"
"M","IT1152A","","10","","","","","","","","","500","19971116","","automatic analyzer","infrared absorption","API","1","Hour","300","200","ROOF","5","Second","1","Day","compressed gases","","EU EoI"
"M","IT1152A","","20","","","","","","","","","500","20000420","20030401","automatic analyzer","chromatography","RANCON BTX","","","300","400","roof","1","Hour","30","Day","","","EU EoI"
"M","IT1152A","","20","","","","","","","","","501","20051216","","automatic analyzer","chromatography","","1","Hour","400","400","ROOF","15","Minute","1","Month","compressed gases","","EU EoI"
"M","IT1152A","","21","","","","","","","","","500","20000420","20030401","automatic analyzer","chromatography","RANCON BTX","","","300","400","roof","1","Hour","30","Day","","","EU EoI"
"M","IT1152A","","21","","","","","","","","","501","20051216","","automatic analyzer","chromatography","","1","Hour","300","200","ROOF","15","Minute","1","Month","compressed gases","","EU EoI"
"M","IT1152A","","38","","","","","","","","","500","19971115","","automatic analyzer","chemiluminescence","API 200 A","1","Hour","300","200","ROOF","5","Second","3","Day","permuation tube","","EU EoI"
"M","IT1157A","","4","","","","","","","","","500","19980102","","automatic analyzer","beta-absorption","ENVIRONMENT SA MPSI 100","","","300","300","roof","2","Hour","0","","standard mass","","EU EoI"
"M","IT1157A","","8","","","","","","","","","500","19980102","","automatic analyzer","chemiluminescence","Thermo Electron Instruments14 B/E","","","350","300","roof","5","Second","24","Hour","permuation tube","","EU EoI"
"M","IT1157A","","9","","","","","","","","","500","19980102","","automatic analyzer","chemiluminescence","THERMO ELECTRON INSTRUMENTS 14 B/E","","","350","300","roof","5","Second","24","Hour","permuation tube","","EU EoI"
"M","IT1157A","","10","","","","","","","","","500","19980102","","automatic analyzer","infrared absorption","Thermo Instr. TE 48","","","350","300","roof","5","Second","24","Hour","compressed gases","","EU EoI"
"M","IT1157A","","38","","","","","","","","","500","19980102","","automatic analyzer","chemiluminescence","Thermo Electron Instruments14 B/E","","","350","300","roof","5","Second","24","Hour","permuation tube","","EU EoI"
"M","IT1158A","","1","","","","","","","","","500","19980102","20020715","automatic analyzer","ultraviolet absorption","Thermo instruments TE 43 A","","","350","300","roof","1","Hour","24","Hour","permuation tube","","EU EoI"
"M","IT1158A","","4","","","","","","","","","500","19980102","20040205","automatic analyzer","beta-absorption","","","","300","300","roof","2","Hour","","","standard mass","","EU EoI"
"M","IT1158A","","8","","","","","","","","","500","19980102","","automatic analyzer","chemiluminescence","Thermo Envir. Instruments TE42","","","350","300","roof","5","Second","24","Hour","permuation tube","","EU EoI"
"M","IT1158A","","9","","","","","","","","","500","19980102","","automatic analyzer","chemiluminescence","Thermo Envir. Instruments TE42","","","350","300","roof","5","Second","24","Hour","permuation tube","","EU EoI"
"M","IT1158A","","10","","","","","","","","","500","19980102","","automatic analyzer","infrared absorption","Thermo Instr. TE 48","","","350","300","roof","5","Second","24","Hour","compressed gases","","EU EoI"
"M","IT1158A","","38","","","","","","","","","500","19980102","","automatic analyzer","chemiluminescence","Thermo Envir. Instruments TE42","","","350","300","roof","5","Second","24","Hour","permuation tube","","EU EoI"
"M","IT1159A","","4","","","","","","","","","500","19980102","","active sampler","gravimetry","SEQUENTIAL SAMPLER","","","300","300","roof","1","natural day","0","","","","EU EoI"
"M","IT1159A","","5","","","","","","","","","500","19990301","","automatic analyzer","beta-absorption","DAS RANCON ADAM C","","","300","300","roof","1","natural day","30","Day","","","EU EoI"
"M","IT1159A","","8","","","","","","","","","500","19980102","","automatic analyzer","chemiluminescence","API200A","","","350","300","roof","5","Second","24","Hour","permuation tube","","EU EoI"