dem_status,station_code,station_name,component_code,component_name,component_short_name,zone_objective_code1,zone_code1,zone_name1,zone_objective_code2,zone_code2,zone_name2,measurement_code,measurement_start_date,measurement_end_date,measurement_method_type,measurement_technique_principle,measurement_equipment,integration_time_frequency,integration_time_unit,height_sampling_point,length_sampling_line,location_sampling_point,sampling_time,sampling_time_unit,calibration_frequency,calibration_unit,calibration_method,calibration_description,body_or_programme
"M","IT0757A","","4","","","","","","","","","500","19910402","20010701","automatic analyzer","","","","","300","150","roof","1","Hour","0","","","","EU EoI"
"M","IT0757A","","5","","","","","","","","","500","20010704","","automatic analyzer","beta-absorption","MP101M","2","Hour","330","","ROOF","2","Hour","2","Month","calibration filter","","EU EoI"
"M","IT0757A","","7","","","","","","","","","500","19910501","","automatic analyzer","ultraviolet absorption","API 400","1","Hour","290","","ROOF","1","Hour","1","Week","permuation tube","","EU EoI"
"M","IT0757A","","8","","","","","","","","","500","19910801","","automatic analyzer","chemiluminescence","Termo Environmental Instruments 42","1","Hour","290","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"A","IT0757A","","9","","","","","","","","","500","20050411","","automatic analyzer","chemiluminescence","Termo Environmental Instruments 42","1","Hour","290","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT0757A","","38","","","","","","","","","500","19910801","","automatic analyzer","chemiluminescence","Termo Environmental Instruments 42","1","Hour","290","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT0804A","","5","","","","","","","","","500","20020421","","automatic analyzer","beta-absorption","DAS RANCON ADAM C","","","250","300","PARK","24","Hour","3","Month","blank filter","","EU EoI"
"M","IT0804A","","7","","","","","","","","","500","19920501","","automatic analyzer","photometry","THERMO ENVIRONMENTAL 49","","","250","300","PARK","30","Second","1","Month","reference measurement meth.","","EU EoI"
"M","IT0804A","","8","","","","","","","","","500","19920501","","automatic analyzer","chemiluminescence","Thermo Envir. Instruments TE42","","","250","300","PARK","30","Second","15","Day","compressed gases","","EU EoI"
"M","IT0804A","","9","","","","","","","","","500","19930501","","automatic analyzer","chemiluminescence","Thermo Envir. Instruments TE42","","","250","300","PARK","30","Second","15","Day","compressed gases","","EU EoI"
"M","IT0804A","","38","","","","","","","","","500","20040101","","automatic analyzer","chemiluminescence","Thermo Envir. Instruments TE42","","","","","PARK","30","Second","1","Month","compressed gases","","EU EoI"
"M","IT0805A","","4","","","","","","","","","500","19920106","20001122","active sampler","gravimetry","FILTER SAMPLING","","","250","300","roof","1","natural day","6","Month","blank filter","","EU EoI"
"M","IT0805A","","8","","","","","","","","","500","19920106","20001122","automatic analyzer","chemiluminescence","Thermo Instr. 42C","","","250","300","roof","20","Second","15","Day","compressed gases","","EU EoI"
"M","IT0805A","","10","","","","","","","","","500","19920106","20001122","automatic analyzer","infrared absorption","Thermo Instr. TE 48","","","250","300","roof","20","Second","1","Month","compressed gases","","EU EoI"
"M","IT0805A","","38","","","","","","","","","500","19920105","20001122","automatic analyzer","UNKNOWN","","","","","","roof","","","","","","","EU EoI"
"M","IT0850A","","8","","","","","","","","","500","19951211","20050628","automatic analyzer","chemiluminescence","Thermo Envir. Instruments TE42","","","4","3","roof","1","Hour","","","","","EU EoI"
"M","IT0850A","","9","","","","","","","","","500","19951211","20050628","automatic analyzer","chemiluminescence","Thermo Envir. Instruments TE42","","","4","3","roof","1","Hour","2","Month","compressed gases","","EU EoI"
"M","IT0850A","","10","","","","","","","","","500","19951211","20050628","automatic analyzer","infrared absorption","THERMO ELECTRON INSTRUMENTS 48","","","4","3","roof","1","Hour","2","Month","compressed gases","","EU EoI"
"M","IT0850A","","38","","","","","","","","","500","19951211","20050628","automatic analyzer","chemiluminescence","Thermo Envir. Instruments TE42","","","4","3","roof","1","Hour","2","Month","compressed gases","","EU EoI"
"M","IT0855A","","1","","","","","","","","","500","19931207","19970115","automatic analyzer","fluorescence","","","","350","200","roof","1","Hour","3","Month","permuation tube","","EU EoI"
"M","IT0855A","","4","","","","","","","","","500","19931207","20030418","automatic analyzer","infrared absorption","SEA Spam","","","-100","-100","roof","1","natural day","1","Month","not applicable","","EU EoI"
"M","IT0855A","","8","","","","","","","","","500","19931207","","automatic analyzer","chemiluminescence","TE 42","1","Hour","300","500","ROOF","30","Second","3","Month","permuation tube","","EU EoI"
"M","IT0855A","","9","","","","","","","","","500","19931207","","automatic analyzer","chemiluminescence","TE 42","1","Hour","300","500","ROOF","30","Second","3","Month","permuation tube","","EU EoI"
"M","IT0855A","","10","","","","","","","","","500","19931207","","automatic analyzer","infrared absorption","Thermo Electron 48","1","Hour","300","500","ROOF","30","Second","3","Month","compressed gases","","EU EoI"
"M","IT0855A","","38","","","","","","","","","500","19931207","","automatic analyzer","chemiluminescence","Thermo Electron 42","1","Hour","300","500","ROOF","30","Second","3","Month","permuation tube","","EU EoI"
"M","IT0892A","","1","","","","","","","","","500","19930602","20020630","automatic analyzer","ultraviolet absorption","Thermo instruments TE 43 A","","","350","300","roof","1","Hour","24","Hour","permuation tube","","EU EoI"
"M","IT0892A","","4","","","","","","","","","500","19930602","20050101","automatic analyzer","beta-absorption","ENVIRONMENT SA MPSI 100","","","300","300","roof","2","Hour","0","","","","EU EoI"
"M","IT0892A","","7","","","","","","","","","500","19930602","","automatic analyzer","ultraviolet absorption","Thermo Instrument Systems TE 49","","","4","3","roof","5","Second","24","Hour","","","EU EoI"
"M","IT0892A","","8","","","","","","","","","500","19930602","","automatic analyzer","chemiluminescence","Thermo Electron Instruments14 B/E","","","350","300","roof","5","Second","24","Hour","permuation tube","","EU EoI"
"M","IT0892A","","9","","","","","","","","","500","19930602","","automatic analyzer","chemiluminescence","THERMO ELECTRON INSTRUMENTS 14 B/E","","","350","300","roof","5","Second","24","Hour","permuation tube","","EU EoI"
"M","IT0892A","","10","","","","","","","","","500","19930602","","automatic analyzer","infrared absorption","Thermo Instr. TE 48","","","350","300","roof","5","Second","24","Hour","compressed gases","","EU EoI"
"M","IT0892A","","20","","","","","","","","","500","19990601","","automatic analyzer","chromatography","Syntech mod. GC 855","","","350","300","roof","15","Minute","15","Day","compressed gases","","EU EoI"
"M","IT0892A","","21","","","","","","","","","500","19990601","","automatic analyzer","chromatography","Syntech mod. GC 855","","","350","300","roof","15","Minute","15","Day","compressed gases","","EU EoI"
"M","IT0892A","","29","","","","","","","","","500","19990601","","active sampler","gravimetry","SEQUENTIAL SAMPLER","","","300","300","roof","1","natural day","0","","","","EU EoI"
"M","IT0892A","","38","","","","","","","","","500","19930602","","automatic analyzer","chemiluminescence","Thermo Electron InstrumentsT/E 14B/E","","","350","300","roof","5","Second","24","Hour","permuation tube","","EU EoI"
"M","IT0893A","","1","","","","","","","","","500","19930602","","automatic analyzer","ultraviolet absorption","Thermo instruments TE 43 A","","","350","300","roof","5","Second","24","Hour","permuation tube","","EU EoI"