dem_status,station_code,station_name,component_code,component_name,component_short_name,zone_objective_code1,zone_code1,zone_name1,zone_objective_code2,zone_code2,zone_name2,measurement_code,measurement_start_date,measurement_end_date,measurement_method_type,measurement_technique_principle,measurement_equipment,integration_time_frequency,integration_time_unit,height_sampling_point,length_sampling_line,location_sampling_point,sampling_time,sampling_time_unit,calibration_frequency,calibration_unit,calibration_method,calibration_description,body_or_programme
"M","IT0709A","","1","","","","","","","","","500","19900101","","automatic analyzer","fluorescence","Mon.Labs 8850","","","250","200","roof","1","Hour","1","Day","","","EU EoI"
"M","IT0709A","","5","","","","","","","","","500","20020930","","automatic analyzer","oscillating microbalance","TEOM 1400 A","","","250","200","roof","","","","","","","EU EoI"
"M","IT0709A","","8","","","","","","","","","500","19900101","","automatic analyzer","chemiluminescence","Mon.Labs 8840","","","250","200","roof","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT0709A","","9","","","","","","","","","500","19900101","","automatic analyzer","chemiluminescence","Mon.Labs 8840","","","250","200","roof","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT0709A","","20","","","","","","","","","500","20020930","","automatic analyzer","chromatography","","","","250","200","roof","","","","","","","EU EoI"
"A","IT0709A","","21","","","","","","","","","500","20061029","","automatic analyzer","chromatography","","","","","","roof","","","","","","","EU EoI"
"M","IT0709A","","38","","","","","","","","","500","19900101","","automatic analyzer","chemiluminescence","Mon.Labs 8840","","","250","200","roof","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT0710A","","1","","","","","","","","","500","19891222","","automatic analyzer","fluorescence","TE 43 A","1","Hour","300","500","ROOF","30","Second","6","Month","permuation tube","","EU EoI"
"M","IT0710A","","7","","","","","","","","","500","19891222","","automatic analyzer","ultraviolet absorption","TE 49","1","Hour","300","500","ROOF","30","Second","6","Month","uv lamp (ozone generator)","","EU EoI"
"M","IT0710A","","8","","","","","","","","","500","19891222","","automatic analyzer","chemiluminescence","API-M200A","1","Hour","300","500","ROOF","30","Second","3","Month","permuation tube","","EU EoI"
"M","IT0710A","","9","","","","","","","","","500","19891222","","automatic analyzer","chemiluminescence","API M 200 A","1","Hour","300","500","ROOF","30","Second","3","Month","permuation tube","","EU EoI"
"M","IT0710A","","10","","","","","","","","","500","19891222","","automatic analyzer","infrared absorption","TE 48","1","Hour","300","500","ROOF","20","Second","2","Month","compressed gases","","EU EoI"
"M","IT0710A","","38","","","","","","","","","500","19891222","","automatic analyzer","chemiluminescence","API M 200 A","1","Hour","300","500","ROOF","30","Second","3","Month","permuation tube","","EU EoI"
"M","IT0721A","","8","","","","","","","","","500","19971001","","automatic analyzer","chemiluminescence","TE 42","1","Hour","300","200","ROOF","5","Second","3","Day","permuation tube","","EU EoI"
"M","IT0721A","","9","","","","","","","","","500","19971001","","automatic analyzer","chemiluminescence","TE 42","1","Hour","300","200","ROOF","5","Second","3","Day","permuation tube","","EU EoI"
"M","IT0721A","","10","","","","","","","","","500","19900206","","automatic analyzer","infrared absorption","TE 48","1","Hour","300","200","ROOF","5","Second","1","Day","compressed gases","","EU EoI"
"M","IT0721A","","38","","","","","","","","","500","19971001","","automatic analyzer","chemiluminescence","TE42","1","Hour","300","200","ROOF","5","Second","3","Day","permuation tube","","EU EoI"
"M","IT0724A","","8","","","","","","","","","500","19900320","","automatic analyzer","chemiluminescence","TE 14B/E","1","Hour","300","200","ROOF","5","Second","3","Day","permuation tube","","EU EoI"
"M","IT0724A","","9","","","","","","","","","500","19900320","","automatic analyzer","chemiluminescence","TE 14B/E","1","Hour","300","200","ROOF","5","Second","3","Day","permuation tube","","EU EoI"
"M","IT0724A","","10","","","","","","","","","500","19900320","","automatic analyzer","infrared absorption","TE 48","1","Hour","300","200","ROOF","5","Second","20","Day","compressed gases","","EU EoI"
"M","IT0724A","","20","","","","","","","","","500","20000420","","automatic analyzer","chromatography","RANCON BTX","1","Hour","300","200","ROOF","5","Second","30","Day","compressed gases","","EU EoI"
"M","IT0724A","","21","","","","","","","","","500","20000420","","automatic analyzer","chromatography","RANCON BTX","1","Hour","300","200","ROOF","5","Second","30","Day","compressed gases","","EU EoI"
"M","IT0724A","","38","","","","","","","","","500","19900320","","automatic analyzer","chemiluminescence","TE 14B/E","1","Hour","300","200","ROOF","5","Second","3","Day","permuation tube","","EU EoI"
"M","IT0726A","","8","","","","","","","","","500","19900321","","automatic analyzer","chemiluminescence","TE 42","1","Hour","300","200","ROOF","5","Second","3","Day","permuation tube","","EU EoI"
"M","IT0726A","","9","","","","","","","","","500","19900321","","automatic analyzer","chemiluminescence","TE 42","1","Hour","300","200","ROOF","5","Second","3","Day","permuation tube","","EU EoI"
"M","IT0726A","","10","","","","","","","","","500","19900321","","automatic analyzer","infrared absorption","TE 48","1","Hour","300","200","ROOF","5","Second","20","Day","compressed gases","","EU EoI"
"M","IT0726A","","38","","","","","","","","","500","19900320","","automatic analyzer","chemiluminescence","TE 42","1","Day","300","200","ROOF","5","Second","3","Day","permuation tube","","EU EoI"
"M","IT0727A","","7","","","","","","","","","500","19980701","","automatic analyzer","ultraviolet absorption","TE 49","1","Hour","300","400","ROOF","5","Second","6","Month","uv lamp (ozone generator)","","EU EoI"
"M","IT0727A","","8","","","","","","","","","500","19900412","","automatic analyzer","chemiluminescence","API 200","","","300","200","roof","1","Hour","3","Day","permuation tube","","EU EoI"
"M","IT0727A","","9","","","","","","","","","500","19900412","","automatic analyzer","chemiluminescence","API 200","1","Hour","300","200","ROOF","5","Second","3","Day","permuation tube","","EU EoI"
"M","IT0727A","","10","","","","","","","","","500","19900412","","automatic analyzer","infrared absorption","TE 48","1","Hour","300","200","ROOF","5","Second","20","Day","compressed gases","","EU EoI"
"M","IT0727A","","38","","","","","","","","","500","19900412","","automatic analyzer","chemiluminescence","API 200","1","Hour","300","200","ROOF","5","Second","3","Day","permuation tube","","EU EoI"
"M","IT0732A","","1","","","","","","","","","500","19911201","","automatic analyzer","fluorescence","API Mod. 100","","","350","300","roof","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT0732A","","7","","","","","","","","","500","19911201","","automatic analyzer","ultraviolet absorption","TE 49 C / TE / USA","","","350","300","roof","","","1","Day","O3 generator stopped","","EU EoI"
"M","IT0732A","","8","","","","","","","","","500","19911201","","automatic analyzer","chemiluminescence","API-M200A","","","350","300","roof","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT0732A","","9","","","","","","","","","500","19911201","","automatic analyzer","chemiluminescence","API-M200A","","","350","300","roof","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT0732A","","10","","","","","","","","","500","19911201","","automatic analyzer","infrared absorption","API-M300A","","","150","0","roof","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT0732A","","38","","","","","","","","","500","19911201","","automatic analyzer","chemiluminescence","API-M200A","","","350","300","roof","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT0738A","","8","","","","","","","","","500","19900101","","automatic analyzer","chemiluminescence","ENVIRONMENT AC 30 M","","","300","250","roof","1","Hour","2","Month","compressed gases","","EU EoI"
"M","IT0738A","","9","","","","","","","","","500","19900101","","automatic analyzer","chemiluminescence","Environnement AC 30 M","","","300","250","roof","1","Hour","2","Month","compressed gases","","EU EoI"