dem_status,station_code,station_name,component_code,component_name,component_short_name,zone_objective_code1,zone_code1,zone_name1,zone_objective_code2,zone_code2,zone_name2,measurement_code,measurement_start_date,measurement_end_date,measurement_method_type,measurement_technique_principle,measurement_equipment,integration_time_frequency,integration_time_unit,height_sampling_point,length_sampling_line,location_sampling_point,sampling_time,sampling_time_unit,calibration_frequency,calibration_unit,calibration_method,calibration_description,body_or_programme
"M","IT0892A","","10","","","","","","","","","500","19930602","","automatic analyzer","infrared absorption","Thermo Instr. TE 48","","","350","300","roof","5","Second","24","Hour","compressed gases","","EU EoI"
"M","IT0892A","","20","","","","","","","","","500","19990601","","automatic analyzer","chromatography","Syntech mod. GC 855","","","350","300","roof","15","Minute","15","Day","compressed gases","","EU EoI"
"M","IT0892A","","38","","","","","","","","","500","19930602","","automatic analyzer","chemiluminescence","Thermo Electron InstrumentsT/E 14B/E","","","350","300","roof","5","Second","24","Hour","permuation tube","","EU EoI"
"M","IT0895A","","5","","","","","","","","","500","19991001","","automatic analyzer","beta-absorption","RANCON ADAM C","1","Day","320","","ROOF","1","natural day","1","Year","calibration filter","","EU EoI"
"M","IT0895A","","8","","","","","","","","","500","19930602","","automatic analyzer","chemiluminescence","API MODEL 200A","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT0895A","","9","","","","","","","","","500","20050407","","automatic analyzer","chemiluminescence","API MODEL 200A","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT0895A","","10","","","","","","","","","500","19930602","","automatic analyzer","infrared absorption","Thermo Environmental model 48","1","Hour","320","","ROOF","1","Hour","1","Day","compressed gases","","EU EoI"
"M","IT0895A","","20","","","","","","","","","500","19991014","","automatic analyzer","chromatography","SYNTECH SPECTRAS MOD. GC855","1","Hour","320","","ROOF","1","Hour","2","Week","compressed gases","","EU EoI"
"M","IT0895A","","21","","","","","","","","","500","19991014","","automatic analyzer","chromatography","SYNTECH SPECTRAS MOD. GC855","1","Hour","320","","ROOF","1","Hour","2","Week","compressed gases","","EU EoI"
"M","IT0895A","","38","","","","","","","","","500","19930602","","automatic analyzer","chemiluminescence","API MODEL 200A","1","Hour","320","","ROOF","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT0897A","","5","","","","","","","","","500","20010201","","automatic analyzer","nephelometry","","","","350","200","roof","1","Hour","","","","","EU EoI"
"M","IT0897A","","8","","","","","","","","","500","19930602","","automatic analyzer","chemiluminescence","HORIBA APNA 350E","","","350","200","roof","1","Hour","1","Day","","","EU EoI"
"M","IT0897A","","9","","","","","","","","","500","19930602","","automatic analyzer","chemiluminescence","HORIBA APHA 350E","","","","","roof","","","","","","","EU EoI"
"M","IT0897A","","10","","","","","","","","","500","19930602","","automatic analyzer","infrared absorption","HORIBA APMA 350E","","","350","200","roof","1","Hour","1","Day","","","EU EoI"
"A","IT0897A","","20","","","","","","","","","500","20040101","","automatic analyzer","UNKNOWN","","","","","","roof","","","","","","","EU EoI"
"A","IT0897A","","38","","","","","","","","","500","20040101","","automatic analyzer","UNKNOWN","","","","","","roof","","","","","","","EU EoI"
"A","IT0897A","","6001","","","","","","","","","500","20040101","","automatic analyzer","UNKNOWN","","","","","","roof","","","","","","","EU EoI"
"M","IT0898A","","8","","","","","","","","","500","19930602","","automatic analyzer","chemiluminescence","HORIBA APNA 350E","","","350","200","roof","1","Hour","1","Day","","","EU EoI"
"A","IT0898A","","9","","","","","","","","","500","19930602","","automatic analyzer","chemiluminescence","","","","","","roof","","","","","","","EU EoI"
"M","IT0898A","","10","","","","","","","","","500","19930602","","automatic analyzer","infrared absorption","HORIBA APMA 350E","","","350","200","roof","1","Hour","1","Day","","","EU EoI"
"A","IT0898A","","38","","","","","","","","","500","20040101","","automatic analyzer","UNKNOWN","","","","","","roof","","","","","","","EU EoI"
"M","IT0902A","","1","","","","","","","","","500","19931001","","automatic analyzer","fluorescence","TE 43 A","","","350","200","roof","1","Hour","1","Month","compressed gases","","EU EoI"
"M","IT0902A","","5","","","","","","","","","500","19950201","","automatic analyzer","gravimetry","THEOM 1400","","","350","200","roof","","","3","Month","calibration filter","","EU EoI"
"M","IT0902A","","7","","","","","","","","","500","19931001","","automatic analyzer","ultraviolet absorption","Thermo instruments TE 49","","","350","200","roof","","","3","Month","reference measurement meth.","","EU EoI"
"M","IT0902A","","8","","","","","","","","","500","19931001","","automatic analyzer","chemiluminescence","TE 42","","","350","200","roof","1","Hour","1","Month","","","EU EoI"
"M","IT0902A","","9","","","","","","","","","500","19931001","","automatic analyzer","chemiluminescence","TE 42","","","350","200","roof","1","Hour","1","Month","","","EU EoI"
"M","IT0902A","","10","","","","","","","","","500","19931001","","automatic analyzer","infrared absorption","TE 48","","","150","0","roof","1","Hour","1","Month","compressed gases","","EU EoI"
"M","IT0902A","","38","","","","","","","","","500","19931001","","automatic analyzer","chemiluminescence","TE 42","","","350","200","roof","1","Hour","1","Month","compressed gases","","EU EoI"
"M","IT0905A","","1","","","","","","","","","500","19931101","","automatic analyzer","fluorescence","DASIBI 4108","","","350","200","roof","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT0905A","","8","","","","","","","","","500","19931101","","automatic analyzer","chemiluminescence","DAISIBI 2108","","","350","200","roof","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT0905A","","9","","","","","","","","","500","19931101","","automatic analyzer","chemiluminescence","DAISIBI 2108","","","350","200","roof","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT0905A","","38","","","","","","","","","500","19931101","","automatic analyzer","chemiluminescence","DAISIBI 2108","","","350","200","roof","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT0906A","","1","","","","","","","","","500","19931101","","automatic analyzer","fluorescence","DASIBI 4108","","","350","200","roof","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT0906A","","5","","","","","","","","","500","19991001","","automatic analyzer","beta-absorption","KIMOTO 186 S","","","350","200","roof","","","1","Month","standard mass","","EU EoI"
"M","IT0906A","","8","","","","","","","","","500","19931101","","automatic analyzer","chemiluminescence","DAISIBI 2108","","","350","200","roof","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT0906A","","9","","","","","","","","","500","19931101","","automatic analyzer","chemiluminescence","DAISIBI 2108","","","350","200","roof","1","Hour","1","Day","permuation tube","","EU EoI"
"M","IT0906A","","10","","","","","","","","","500","19931101","","automatic analyzer","infrared absorption","DAISIBI 3008","","","350","200","roof","1","Hour","1","Day","compressed gases","","EU EoI"
"A","IT0906A","","20","","","","","","","","","500","20060918","","automatic analyzer","chromatography","","","","","","roof","","","","","","","EU EoI"
"A","IT0906A","","21","","","","","","","","","500","20060918","","automatic analyzer","chromatography","","","","","","roof","","","","","","","EU EoI"