dem_status,station_code,station_name,component_code,component_name,component_short_name,zone_objective_code1,zone_code1,zone_name1,zone_objective_code2,zone_code2,zone_name2,measurement_code,measurement_start_date,measurement_end_date,measurement_method_type,measurement_technique_principle,measurement_equipment,integration_time_frequency,integration_time_unit,height_sampling_point,length_sampling_line,location_sampling_point,sampling_time,sampling_time_unit,calibration_frequency,calibration_unit,calibration_method,calibration_description,body_or_programme
"M","IT1070A","","20","","","","","","","","","500","19970101","","automatic analyzer","flame ionization","Chrompack CP 7001","","","","","roof","1","Hour","3","Month","compressed gases","","EU EoI"
"M","IT1070A","","21","","","","","","","","","500","19970101","","automatic analyzer","flame ionization","Chrompack CP 7001","","","","","roof","1","Hour","3","Month","compressed gases","","EU EoI"
"M","IT1070A","","32","","","","","","","","","500","19970101","","automatic analyzer","flame ionization","NIRA","","","","","roof","1","Hour","1","Month","compressed gases","","EU EoI"
"M","IT1070A","","41","","","","","","","","","500","19970101","","automatic analyzer","flame ionization","NIRA","","","","","roof","1","Hour","1","Month","compressed gases","","EU EoI"
"M","IT1070A","","431","","","","","","","","","500","19970101","","automatic analyzer","flame ionization","Chrompack CP 7001","","","","","roof","1","Hour","3","Month","compressed gases","","EU EoI"
"M","IT1070A","","482","","","","","","","","","500","19970101","","automatic analyzer","flame ionization","Chrompack CP 7001","","","","","roof","1","Hour","3","Month","compressed gases","","EU EoI"
"M","IT1076A","","1","","","","","","","","","500","19960801","","automatic analyzer","fluorescence","ML9850/SO2","","","340","440","roof","1","Hour","24","Hour","permuation tube","","EU EoI"
"M","IT1076A","","5","","","","","","","","","500","19960801","","automatic analyzer","beta-absorption","Environnement MP101M","","","450","290","roof","2","Hour","6","Month","calibration filter","","EU EoI"
"M","IT1076A","","7","","","","","","","","","500","19960801","","automatic analyzer","ultraviolet absorption","ML 9812","","","340","440","roof","1","Hour","3","Day","uv lamp (ozone generator)","","EU EoI"
"M","IT1076A","","8","","","","","","","","","500","19960801","","automatic analyzer","chemiluminescence","ML 9841A","","","340","440","roof","1","Hour","7","Day","permuation tube","","EU EoI"
"M","IT1076A","","9","","","","","","","","","500","19960801","","automatic analyzer","chemiluminescence","ML 9841A","","","340","440","roof","1","Hour","7","Day","compressed gases","","EU EoI"
"M","IT1076A","","10","","","","","","","","","500","19960801","","automatic analyzer","infrared absorption","ML9830","","","340","440","roof","1","Hour","7","Day","compressed gases","","EU EoI"
"M","IT1076A","","12","","","","","","","","","500","20030101","","active sampler","atomic absorption spectrometry","","","","340","","roof","24","Hour","","","","","EU EoI"
"A","IT1076A","","14","","","","","","","","","500","19960801","","automatic analyzer","UNKNOWN","","","","","","roof","","","","","","","EU EoI"
"A","IT1076A","","15","","","","","","","","","500","20050101","","active sampler","atomic absorption spectrometry","","","","340","200","roof","","","","","","","EU EoI"
"M","IT1076A","","20","","","","","","","","","500","20020215","","automatic analyzer","chromatography","SRI Instruments 8610","","","340","440","roof","1","Hour","2","Week","compressed gases","","EU EoI"
"M","IT1076A","","21","","","","","","","","","500","20020215","","automatic analyzer","chromatography","SRI Instruments 8610","","","340","440","roof","1","Hour","2","Week","compressed gases","","EU EoI"
"M","IT1076A","","38","","","","","","","","","500","19960801","","automatic analyzer","chemiluminescence","ML 9841A","","","340","440","roof","1","Hour","7","Day","compressed gases","","EU EoI"
"M","IT1076A","","482","","","","","","","","","500","20020215","","automatic analyzer","chromatography","SRI Instruments 8610","","","340","440","roof","1","Hour","2","Week","compressed gases","","EU EoI"
"M","IT1078A","","1","","","","","","","","","500","19960801","20060831","automatic analyzer","fluorescence","ML9850/SO2","","","340","440","roof","1","Hour","24","Hour","permuation tube","","EU EoI"
"M","IT1078A","","5","","","","","","","","","500","19960801","","automatic analyzer","beta-absorption","Environnement MP101M","","","450","290","roof","2","Hour","6","Month","calibration filter","","EU EoI"
"M","IT1078A","","8","","","","","","","","","500","19960801","","automatic analyzer","chemiluminescence","ML 9841A","","","340","440","roof","1","Hour","7","Day","permuation tube","","EU EoI"
"M","IT1078A","","9","","","","","","","","","500","19960801","","automatic analyzer","chemiluminescence","ML 9841A","","","340","440","roof","1","Hour","7","Day","compressed gases","","EU EoI"
"M","IT1078A","","10","","","","","","","","","500","19960801","","automatic analyzer","infrared absorption","ML9830","","","340","440","roof","1","Hour","7","Day","compressed gases","","EU EoI"
"M","IT1078A","","12","","","","","","","","","500","20030101","","active sampler","atomic absorption spectrometry","","","","340","160","KERBSIDE","24","Hour","","","","","EU EoI"
"A","IT1078A","","14","","","","","","","","","500","19960801","","automatic analyzer","UNKNOWN","","","","","","roof","","","","","","","EU EoI"
"A","IT1078A","","15","","","","","","","","","500","20050101","","active sampler","atomic absorption spectrometry","","","","340","160","roof","","","","","","","EU EoI"
"M","IT1078A","","38","","","","","","","","","500","19960801","","automatic analyzer","chemiluminescence","ML 9841A","","","340","440","roof","1","Hour","7","Day","compressed gases","","EU EoI"
"M","IT1079A","","1","","","","","","","","","500","19960801","","automatic analyzer","fluorescence","ML9850/SO2","","","340","440","roof","1","Hour","24","Hour","permuation tube","","EU EoI"
"M","IT1079A","","5","","","","","","","","","500","19960801","","automatic analyzer","beta-absorption","Environnement MP101M","","","450","290","roof","2","Hour","6","Month","calibration filter","","EU EoI"
"M","IT1079A","","7","","","","","","","","","500","19960801","","automatic analyzer","ultraviolet absorption","ML 9812","","","340","440","roof","1","Hour","3","Day","uv lamp (ozone generator)","","EU EoI"
"M","IT1079A","","8","","","","","","","","","500","19960801","","automatic analyzer","chemiluminescence","ML 9841A","","","340","440","roof","1","Hour","7","Day","permuation tube","","EU EoI"
"M","IT1079A","","9","","","","","","","","","500","19960801","","automatic analyzer","chemiluminescence","ML 9841A","","","340","440","roof","1","Hour","7","Day","compressed gases","","EU EoI"
"M","IT1079A","","10","","","","","","","","","500","19960801","","automatic analyzer","infrared absorption","ML9830","","","340","440","roof","1","Hour","7","Day","compressed gases","","EU EoI"
"M","IT1079A","","12","","","","","","","","","500","20030101","","active sampler","atomic absorption spectrometry","","","","340","160","roof","24","Hour","","","","","EU EoI"
"A","IT1079A","","14","","","","","","","","","500","19960801","","automatic analyzer","UNKNOWN","","","","","","roof","","","","","","","EU EoI"
"A","IT1079A","","15","","","","","","","","","500","19960801","","automatic analyzer","UNKNOWN","","","","","","roof","","","","","","","EU EoI"
"M","IT1079A","","20","","","","","","","","","500","20020220","","automatic analyzer","chromatography","SRI Instruments 8610","","","340","440","roof","1","Hour","2","Week","compressed gases","","EU EoI"