dem_status,station_code,station_name,component_code,component_name,component_short_name,zone_objective_code1,zone_code1,zone_name1,zone_objective_code2,zone_code2,zone_name2,measurement_code,measurement_start_date,measurement_end_date,measurement_method_type,measurement_technique_principle,measurement_equipment,integration_time_frequency,integration_time_unit,height_sampling_point,length_sampling_line,location_sampling_point,sampling_time,sampling_time_unit,calibration_frequency,calibration_unit,calibration_method,calibration_description,body_or_programme
"M","IT1529A","","10","","","","","","","","","500","20020101","","automatic analyzer","infrared absorption","API-M300A","","","150","0","roof","1","Hour","0","","","","EU EoI"
"M","IT1529A","","20","","","","","","","","","500","20020101","","automatic analyzer","chromatography","SINTECH SPECTRAS BTX GC 855","","","300","0","roof","1","Hour","0","","","","EU EoI"
"M","IT1529A","","38","","","","","","","","","500","20020101","","automatic analyzer","chemiluminescence","API 200 A","","","300","0","roof","1","Hour","0","","","","EU EoI"
"M","IT1532A","","5","","","","","","","","","500","20020206","","active sampler","gravimetry","","","","200","","roof","1","natural day","","","","","EU EoI"
"M","IT1532A","","7","","","","","","","","","500","20020206","","automatic analyzer","ultraviolet absorption","API 400","","","300","0","roof","1","Hour","0","","","","EU EoI"
"M","IT1532A","","8","","","","","","","","","500","20020206","","automatic analyzer","chemiluminescence","API 200","","","300","0","roof","1","Hour","0","","","","EU EoI"
"M","IT1532A","","10","","","","","","","","","500","20020206","","automatic analyzer","infrared absorption","API 300","","","150","0","roof","1","Hour","0","","","","EU EoI"
"M","IT1532A","","38","","","","","","","","","500","20020206","","automatic analyzer","chemiluminescence","API 200","","","300","0","roof","1","Hour","0","","","","EU EoI"
"M","IT1536A","","8","","","","","","","","","500","20020809","","automatic analyzer","chemiluminescence","","","","","","roof","","","","","","","EU EoI"
"M","IT1536A","","9","","","","","","","","","500","20020809","","automatic analyzer","chemiluminescence","","","","","","roof","","","","","","","EU EoI"
"M","IT1537A","","5","","","","","","","","","500","20040318","","automatic analyzer","beta-absorption","","","","","","roof","1","Hour","","","","","EU EoI"
"M","IT1537A","","10","","","","","","","","","500","20010511","","automatic analyzer","infrared absorption","","","","","","roof","1","Hour","","","","","EU EoI"
"M","IT1538A","","1","","","","","","","","","500","20021128","","automatic analyzer","ultraviolet absorption","","","","","","roof","","","","","","","EU EoI"
"M","IT1538A","","5","","","","","","","","","500","20030212","","automatic analyzer","beta-absorption","","","","","","roof","","","","","","","EU EoI"
"M","IT1538A","","7","","","","","","","","","500","20030605","","automatic analyzer","ultraviolet absorption","","","","","","roof","","","","","","","EU EoI"
"M","IT1538A","","8","","","","","","","","","500","20021128","","automatic analyzer","chemiluminescence","","","","","","roof","","","","","","","EU EoI"
"M","IT1538A","","9","","","","","","","","","500","20021128","","automatic analyzer","chemiluminescence","","","","","","roof","","","","","","","EU EoI"
"M","IT1538A","","10","","","","","","","","","500","20030311","","automatic analyzer","infrared absorption","","","","","","roof","","","","","","","EU EoI"
"M","IT1538A","","20","","","","","","","","","500","20021128","","automatic analyzer","chromatography","","","","","","roof","","","","","","","EU EoI"
"M","IT1538A","","38","","","","","","","","","500","20021128","","automatic analyzer","chemiluminescence","","","","","","roof","","","","","","","EU EoI"
"M","IT1539A","","1","","","","","","","","","500","20010101","","automatic analyzer","ultraviolet absorption","","","","","","roof","1","Hour","","","","","EU EoI"
"M","IT1539A","","7","","","","","","","","","500","20010101","","automatic analyzer","ultraviolet absorption","","","","","","roof","","","","","","","EU EoI"
"M","IT1539A","","8","","","","","","","","","500","20010101","","automatic analyzer","chemiluminescence","","","","","","roof","","","","","","","EU EoI"
"M","IT1539A","","9","","","","","","","","","500","20010101","","automatic analyzer","chemiluminescence","","","","","","roof","","","","","","","EU EoI"
"M","IT1539A","","38","","","","","","","","","500","20010101","","automatic analyzer","chemiluminescence","","","","","","roof","","","","","","","EU EoI"
"M","IT1542A","","8","","","","","","","","","500","20020617","","automatic analyzer","chemiluminescence","","","","","","roof","","","1","Week","","","EU EoI"
"M","IT1542A","","9","","","","","","","","","500","20020617","","automatic analyzer","chemiluminescence","","","","","","roof","","","1","Week","","","EU EoI"
"M","IT1543A","","1","","","","","","","","","500","20020101","","automatic analyzer","ultraviolet absorption","","","","0","0","roof","0","","0","","","","EU EoI"
"M","IT1543A","","7","","","","","","","","","500","20010101","","automatic analyzer","ultraviolet absorption","","","","","","roof","","","","","","","EU EoI"
"M","IT1544A","","1","","","","","","","","","500","20020926","","automatic analyzer","fluorescence","","","","","","roof","","","","","","","EU EoI"
"M","IT1544A","","5","","","","","","","","","500","20020926","","automatic analyzer","gravimetry","","","","","","roof","","","","","","","EU EoI"
"M","IT1544A","","8","","","","","","","","","500","20020926","","automatic analyzer","chemiluminescence","","","","","","roof","","","","","","","EU EoI"
"M","IT1544A","","9","","","","","","","","","500","20020926","","automatic analyzer","chemiluminescence","","","","","","roof","","","","","","","EU EoI"
"M","IT1545A","","1","","","","","","","","","500","20020626","","automatic analyzer","fluorescence","","","","","","roof","","","","","","","EU EoI"
"M","IT1546A","","1","","","","","","","","","500","20020702","","automatic analyzer","fluorescence","","","","","","roof","","","","","","","EU EoI"
"M","IT1546A","","8","","","","","","","","","500","20020702","","automatic analyzer","chemiluminescence","","","","","","roof","","","","","","","EU EoI"
"M","IT1546A","","9","","","","","","","","","500","20020702","","automatic analyzer","chemiluminescence","","","","","","roof","","","","","","","EU EoI"
"M","IT1547A","","8","","","","","","","","","500","20020626","","automatic analyzer","chemiluminescence","","","","","","roof","","","1","Week","","","EU EoI"
"M","IT1547A","","9","","","","","","","","","500","20020626","","automatic analyzer","chemiluminescence","","","","","","roof","","","1","Week","","","EU EoI"
